Fatigue induite par l'électrostimulation neuromusculaire (notice n° 1009354)

détails MARC
000 -LEADER
fixed length control field 02840cam a2200265 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250125140250.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Maffiuletti, Nicola Angelo
Relator term author
245 00 - TITLE STATEMENT
Title Fatigue induite par l'électrostimulation neuromusculaire
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2010.<br/>
500 ## - GENERAL NOTE
General note 15
520 ## - SUMMARY, ETC.
Summary, etc. RésuméLa fatigue musculaire associée à l’application de l’électrostimulation conventionnelle (fréquence 50 –120 Hz ; largeur impulsion 0,2 –0,4 ms) se manifeste par une diminution très précoce et marquée de la force évoquée ainsi que de la force maximale volontaire. Ce phénomène constitue l’un des facteurs limitant l’utilisation de cette technique dans le domaine clinique et sportif. Une série de contractions tétaniques évoquées par électrostimulation provoque essentiellement une diminution de l’excitabilité membranaire (fatigue de haute fréquence), même si des signes physiologiques de fatigue de basse fréquence peuvent apparaître de façon retardée (dommages musculaires). L’ensemble des altérations métaboliques et neuromusculaires induites par l’électrostimulation trouve son explication dans le recrutement spécifique aux contractions évoquées artificiellement. L’importance et l’origine de la fatigue induite par l’électrostimulation à impulsions larges (1 ms), qui est une technique alternative, méritent d’être investiguées.
520 ## - SUMMARY, ETC.
Summary, etc. Fatigue induced by neuromuscular electrical stimulationThe application of conventional neuromuscular electrical stimulation (frequency 50 –120 Hz; pulse width 0.2 –0.4 ms) results in a rapid and marked decline in evoked force and maximal voluntary contraction force ( i.e., muscle fatigue), which inevitably affects its effectiveness in both clinical and sport training settings. A series of electrically induced contractions mainly provoke neuromuscular transmission-propagation failure (high-frequency fatigue), while low-frequency fatigue signs could also appear in the first few days after exercise. The metabolic and neuromuscular alterations induced by electrical stimulation are largely explained by the specific motor unit recruitment pattern of evoked contractions. The extent of muscle fatigue induced by wide pulse (1 ms) electrical stimulation, which is an emerging technique, and the underlying mechanisms remain to be investigated.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element onde M
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element quadriceps
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element EMG
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element force maximale volontaire
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element maximal voluntary contraction
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element quadriceps
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element EMG
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element M wave
786 0# - DATA SOURCE ENTRY
Note Movement & Sport Sciences - Science & Motricité | 70 | 2 | 2010-06-01 | p. 61-67 | 2118-5735
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-movement-and-sport-sciences-2010-2-page-61?lang=fr&redirect-ssocas=7080">https://shs.cairn.info/revue-movement-and-sport-sciences-2010-2-page-61?lang=fr&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025