Influence of knee flexion angle at initial contact and hip internal rotation on ‘stiff-knee’ gait: A dynamical 3D approach (notice n° 1009823)

détails MARC
000 -LEADER
fixed length control field 02456cam a2200301 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250125140405.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Pimenta dos Santos, Alexandra
Relator term author
245 00 - TITLE STATEMENT
Title Influence of knee flexion angle at initial contact and hip internal rotation on ‘stiff-knee’ gait: A dynamical 3D approach
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2016.<br/>
500 ## - GENERAL NOTE
General note 55
520 ## - SUMMARY, ETC.
Summary, etc. Le déficit de flexion du genou est un des troubles de marche les plus fréquents chez les enfants atteints de paralysie cérébrale. Souvent associé à une marche « genoux fléchis » et à une rotation interne de hanche, l’influence de celles-ci sur la marche en « genou raide » demeure peu connue. Un simulateur de marche 3D corps complet a été conçu sur la base du modèle du robot iCUB. Plusieurs allures de marche sont synthétisés sous XDE, avec des angles de flexion de genou au contact initial et de rotation interne de hanche variant respectivement de 37˚ à 64˚ et de 0˚ à 30˚ en unilatéral comme en bilatéral. On constate que le fait d’avoir les « genoux fléchis » à l’attaque du pas majore la marche en « genou raide ».
520 ## - SUMMARY, ETC.
Summary, etc. Lack of knee flexion is one of the most common gait deviations in cerebral palsy children. Although in many cases this gait deviation is associated with a crouch gait and/or a hip internal rotation, the impact of these factors on stiff-knee gait remains poorly pursued. A 3D full body gait simulator was designed based on an iCUB’s robot model. Gait cycles were synthesized in XDE. Different gait patterns were simulated with a varying knee flexion angle at initial contact from 37˚ to 64˚ and minimum hip internal rotation from 0˚ to 30˚, both unilaterally and bilaterally. We concluded that knee flexion angle at initial contact has an influence on stiff-knee gait.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element marche pathologique
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element simulation 3D
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element genou raide
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element paralysie cérébrale
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element 3D simulation
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element stiff-knee gait
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element pathological gait
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element cerebral palsy
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Ben Amar, Faiz
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Bidaud, Philippe
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Desailly, Éric
Relator term author
786 0# - DATA SOURCE ENTRY
Note Movement & Sport Sciences - Science & Motricité | 93 | 3 | 2016-09-22 | p. 71-76 | 2118-5735
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-movement-and-sport-sciences-2016-3-page-71?lang=fr&redirect-ssocas=7080">https://shs.cairn.info/revue-movement-and-sport-sciences-2016-3-page-71?lang=fr&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025