The validity of a head-worn inertial sensor for measurements of swimming performance (notice n° 1010473)

détails MARC
000 -LEADER
fixed length control field 03606cam a2200301 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250125140552.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Butterfield, James
Relator term author
245 00 - TITLE STATEMENT
Title The validity of a head-worn inertial sensor for measurements of swimming performance
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2021.<br/>
500 ## - GENERAL NOTE
General note 15
520 ## - SUMMARY, ETC.
Summary, etc. La validité du dispositif TritonWear® pour mesurer les performances en natation a été étudiée avec un objectif analytique prédéterminé de 6 %. Vingt jeunes nageurs ont réalisé une épreuve de 100 m dans une piscine de 25 m, ® en brasse ou en nage libre en portant le dispositif TritonWear, tout en étant filmés au-dessus et en dessous de l’eau avec trois caméras. Les limites de concordance à 95 % (LoA à 95 %) et le coefficient de variation (CV %) ont été utilisés pour calculer l’erreur. Des biais systématiques ( p &lt; 0,05) ont été trouvés entre les deux systèmes uniquement pour la distance parcourue par coup de bras en brasse. La concordance des métriques en nage libre variait entre 1,06 % et 10,40 % du CV, sauf pour la distance par coup de bras (CV = 14,64 %) et le temps passé sous l’eau (CV = 18,15 %). Les valeurs pour la brasse variaient entre 0,95 % et 13,74% du CV, sauf pour le temps passé sous l’eau (CV = 25,76 %). Les plus petites erreurs ont été trouvées pour les temps intermédiaires, la vitesse, le nombre de coups de bras et la fréquence des coups de bras, pour les deux nages (tous &lt; 5 % de CV). Le TritonWear® peut être utilisé pour les mesures de performance de base, telles que le temps intermédiaire et la vitesse, mais l’erreur sur des paramètres plus complexes, telles que la durée d’immersion ou les temps de virage, ne permet pas d’identifier des modifications de ces paramètres.
520 ## - SUMMARY, ETC.
Summary, etc. The validity of the TritonWear® device to measure swimming performance was investigated, with a pre-determined analytical goal of 6%. Twenty youth swimmers completed a 100 m swim in a 25 m pool, swimming breaststroke or freestyle wearing the TritonWear® device, whilst being filmed above and below water with three cameras. 95% limits of agreement (95% LoA) and coefficient of variation (CV %) were used to calculate error. Systematic biases ( P &lt; 0.05) were found between the two systems only for distance per stroke during breaststroke. Freestyle metrics agreement ranged between 1.06% and 10.40% CV, except for distance per stroke (CV = 14.64%), and time underwater (CV = 18.15%). Breaststroke metrics ranged between 0.95% and 13.74% CV, except for time underwater (CV = 25.76%). The smallest errors were found for split-times, speed, stroke-count and stroke-rate, across both strokes (al &lt; 5% CV). The TritonWear® can be used for basic metrics of performance, such as split-time and speed but the error of more complex measurements, such as time underwater or turn-times, renders them unable to identify typical performance changes.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element micro-technologie
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element sports nautiques
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element erreur de mesure
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element micro-technology
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element water sports
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element measurement error
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Tallent, Jamie
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Patterson, Stephen David
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Jeffries, Owen
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Howe, Louis
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Waldron, Mark
Relator term author
786 0# - DATA SOURCE ENTRY
Note Movement & Sport Sciences - Science & Motricité | 114 | 4 | 2021-11-22 | p. 3-8 | 2118-5735
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-movement-and-sport-sciences-2021-4-page-3?lang=en&redirect-ssocas=7080">https://shs.cairn.info/revue-movement-and-sport-sciences-2021-4-page-3?lang=en&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025