Development and assessment of test-retest reliability of a new field test to evaluate lower-limb muscle fatigability in young adults (notice n° 1010541)
[ vue normale ]
000 -LEADER | |
---|---|
fixed length control field | 04544cam a2200349 4500500 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250125140601.0 |
041 ## - LANGUAGE CODE | |
Language code of text/sound track or separate title | fre |
042 ## - AUTHENTICATION CODE | |
Authentication code | dc |
100 10 - MAIN ENTRY--PERSONAL NAME | |
Personal name | Souron, Robin |
Relator term | author |
245 00 - TITLE STATEMENT | |
Title | Development and assessment of test-retest reliability of a new field test to evaluate lower-limb muscle fatigability in young adults |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Date of publication, distribution, etc. | 2024.<br/> |
500 ## - GENERAL NOTE | |
General note | 85 |
520 ## - SUMMARY, ETC. | |
Summary, etc. | L’objectif de cette étude était de développer un nouveau test écologique de terrain pour évaluer la fatigabilité des muscles des membres inférieurs chez des jeunes adultes. Dans l’expérience A, nous avons conçu et évalué la capacité d’un test intermittent impliquant l’exercice de chaise isométrique pour induire un niveau progressif de fatigabilité musculaire, détectée par la cinétique des changements de hauteur de saut en squat jump (SJH) et de temps de lever de chaise (STST), calculée à l’aide de deux applications mobiles à des fins de faisabilité. Dans l’expérience B, les participants ont effectué le même test lors de deux journées différentes pour évaluer la reproductibilité test-retest. Les cinétiques des changements de nos indicateurs de fatigabilité ont été enregistrées à isotime, à l’épuisement et 2 min après l’arrêt de l’exercice. La variation minimale détectable (MDC95) ainsi que les coefficients de fiabilité absolue (CVTE) et relative (ICC3-1) ont été évalués. Dans l’expérience A, nous avons observé une diminution progressive des performances pour le SJH et le STST tout au long de la tâche, atteignant à l’épuisement des changements moyens de −22±11% et +31±13%. L’analyse des données individuelles a montré une diminution des performances pour le SJH et le STST supérieure au MDC95 chez 85% et 95% des participants. Dans l’expérience B, les changements dans nos indicateurs de fatigabilité ont montré une excellente fiabilité inter-session à isotime, à l’épuisement et 2 min après l’arrêt de l’exercice pour le SJH (ICC3-1 > 0,97 ; CVTE < 7,5%) et le STST (ICC3-1 > 0,92 ; CVTE < 3,3%). Ce test est réalisable et fiable, ce qui le rend particulièrement prometteur pour évaluer la fatigue musculaire, que ce soit dans des environnements appliqués tels que la clinique ou en laboratoire. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | We aimed to develop a new field test to evaluate lower-limb muscle fatigability in young adults. In Experiment–A, we developed and determined the ability of an intermittent isometric wall-squat test to induce progressive level of muscle fatigability, as detected by the kinetics of changes in squat-jump height (SJH) and sit-to-stand time (STST) computed using two smartphone applications for feasibility purposes. In Experiment–B, participants performed the same test on two different days for reliability assessment. Kinetics of changes in our fatigability indicators were registered at isotime, exhaustion, and Post2min. The minimal detectable change (MDC95) and the absolute (CVTE) and relative (ICC3-1) reliability coefficients were assessed. In Experiment–A, we reported a progressive decrease in performance for SJH and STST throughout the task, reaching at exhaustion mean changes of −22±11% and +31±13%. Individual data-analysis showed decrease in performance for SJH and STST greater than the MDC95 in 85% and 95% of participants. In Experiment–B, changes in our fatigability indicators demonstrated excellent inter-session reliability at isotime, exhaustion and Post2min for SJH (ICC3-1 > 0.97; CVTE < 7.5%) and STST (ICC3-1 > 0.92; CVTE < 3.3%). This test is feasible and reliable, making it very promising for evaluating muscle fatigability in applied (e.g. clinical) and laboratory settings. |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | puissance musculaire |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | applications mobiles |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | Fatigabilité |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | endurance musculaire |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | testing musculaire |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | muscle testing |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | muscle power |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | muscle endurance |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | smartphone applications |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | Performance fatigability |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Colard, Julian |
Relator term | author |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ruiz-Cárdenas, Juan D. |
Relator term | author |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Beltran, Anicée |
Relator term | author |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Duché, Pascale |
Relator term | author |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Gruet, Mathieu |
Relator term | author |
786 0# - DATA SOURCE ENTRY | |
Note | Movement & Sport Sciences - Science & Motricité | 124 | 2 | 2024-04-16 | p. 37-47 | 2118-5735 |
856 41 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="https://shs.cairn.info/revue-movement-and-sport-sciences-2024-2-page-37?lang=en&redirect-ssocas=7080">https://shs.cairn.info/revue-movement-and-sport-sciences-2024-2-page-37?lang=en&redirect-ssocas=7080</a> |
Pas d'exemplaire disponible.
Réseaux sociaux