Intérêt de la surveillance des voies d’abord par monitorage des pressions de perfusion en néonatalogie (notice n° 1020416)
[ vue normale ]
000 -LEADER | |
---|---|
fixed length control field | 02623cam a2200277 4500500 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250125165121.0 |
041 ## - LANGUAGE CODE | |
Language code of text/sound track or separate title | fre |
042 ## - AUTHENTICATION CODE | |
Authentication code | dc |
100 10 - MAIN ENTRY--PERSONAL NAME | |
Personal name | Guy, B. |
Relator term | author |
245 00 - TITLE STATEMENT | |
Title | Intérêt de la surveillance des voies d’abord par monitorage des pressions de perfusion en néonatalogie |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Date of publication, distribution, etc. | 1992.<br/> |
500 ## - GENERAL NOTE | |
General note | 82 |
520 ## - SUMMARY, ETC. | |
Summary, etc. | L’occlusion des cathéters présente des risques exacerbés en néonatalogie. Un moyen efficace de prévenir ces occlusions a été apporté par la surveillance de la pression de perfusion, notamment à l’aide d’une pompe volumétrique munie d’un secteur de pression. Cette technique permet deux surveillances : affichage permanent de la pression de perfusion et réglage journalier d’une alarme de surpression.Les pressions de perfusion sont stables autour de +/– 30 cm H2O d’une pression moyenne. Ainsi, toute élévation au-dessus de cet écart est suspecte. La surveillance régulière de la pression qui a été adoptée depuis par le service permet de diagnostiquer toute surpression anormale, due par exemple à une occlusion.L’alarme de surpression est réglée optimalement à 30 cm H2O au-dessus de la pression de perfusion. Son efficacité porte sur la rapidité pour déceler une amorce d’occlusion et ainsi que la détection précoce des diffusions tissulaires. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The consequences of occlusions in catheters are known to be particularly acute in neonates.The monitoring of infusion pressure, by a variable pressure pump, is reported to prevent efficiently such occlusions. Two ways of monitoring can be recommended : easy viewing of infusion pressure and programming a pressure limit.Infusion pressure is recorted at around +/– 30 cm water pressure of the mean day pressure. In consequence, a raise above this gap must be considered as suspect. The regular viewing of this measurement is a way of predicting such problems as occlusions.The optimum pressure limit is programmed at 30 cm water pressure above the infusion pressure. This alarm may identify the beginning occlusions or reduce the extent of tissue damage in early detecting of an infiltration. |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | surveillance |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | néonatalogie |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | voies d’abord |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | pompe |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | pumps |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | catheters |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | neonates |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
Topical term or geographic name as entry element | monitoring |
700 10 - ADDED ENTRY--PERSONAL NAME | |
Personal name | Pons de Vincent, J.F. |
Relator term | author |
786 0# - DATA SOURCE ENTRY | |
Note | Recherche en soins infirmiers | 30 | 3 | 1992-09-01 | p. 21-26 | 0297-2964 |
856 41 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="https://shs.cairn.info/revue-recherche-en-soins-infirmiers-1992-3-page-21?lang=fr&redirect-ssocas=7080">https://shs.cairn.info/revue-recherche-en-soins-infirmiers-1992-3-page-21?lang=fr&redirect-ssocas=7080</a> |
Pas d'exemplaire disponible.
Réseaux sociaux