Estimation of glomerular filtration rate in a pediatric setting at the Charles-de-Gaulle Pediatric University Hospital in Ouagadougou, Burkina Faso: A comparison of the Schwartz and Pottel methods (notice n° 1573399)

détails MARC
000 -LEADER
fixed length control field 02570cam a2200265 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251214030101.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Savadogo, Hamidou
Relator term author
245 00 - TITLE STATEMENT
Title Estimation of glomerular filtration rate in a pediatric setting at the Charles-de-Gaulle Pediatric University Hospital in Ouagadougou, Burkina Faso: A comparison of the Schwartz and Pottel methods
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2025.<br/>
500 ## - GENERAL NOTE
General note 17
520 ## - SUMMARY, ETC.
Summary, etc. Glomerular filtration rate (GFR) is the best indicator of kidney function. In clinical practice, it is most often estimated using equations derived from serum creatinine levels. The objective of our study was to evaluate the performance of two GFR estimators in a pediatric hospital setting in Ouagadougou. This was a prospective study conducted from October 1, 2018 to April 4, 2019. It included children aged 5 to 15 years hospitalized in the medical pediatrics department of the Charles de-Gaulle Pediatric University Hospital. The gold standard was creatinine clearance calculated from a 24-hour urine collection. One hundred patients were included in the study. The median age was 9 years and the sex ratio was 1.5. The median creatinine clearance was 79.69 mL/min/1.73 m². The median GFR estimated using the Schwartz-2009 and Pottel formulas were 86.07 and 84.31 mL/min/1.73 m², respectively. For 95% of patients, the differences between the GFR estimated by the Schwartz formula and the measured creatinine clearance ranged from -95.55 to 105.52 mL/min/1.73 m². These differences range from -101.38 to 102.52 mL/min/1.73 m² for the GFR estimated by the Pottel formula. Although the Schwartz-2009 and Pottel formulas were developed from populations different from our own, they are suitable for our context. However, the Pottel formula appears to have a certain superiority over the Schwartz formula, with narrower limits of agreement and a lower degree of overestimation of creatinine clearance.
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Tamini Toguyeni, Laure
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Tiendrébéogo, Arnaud
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Bihoun, Biebo
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Tarihidiga, Aimée
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Kaboré, Aïssata
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Bonzi, Yeremade Juste
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Saga Ouermi, Alain
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Coulibaly, Gérard
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Yé-Ouattara, Diarra
Relator term author
786 0# - DATA SOURCE ENTRY
Note Néphrologie & Thérapeutique | Volume 21 | 4 | 2025-09-25 | p. 241-247 | 1769-7255
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://stm.cairn.info/journal-nephrologie-therapeutique-2025-4-page-241?lang=en&redirect-ssocas=7080">https://stm.cairn.info/journal-nephrologie-therapeutique-2025-4-page-241?lang=en&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025