Impact des hyperleucocytoses sur les paramètres érythrocytaires de la numération : prise en charge par l’analyseur XN-10 RET (notice n° 275499)

détails MARC
000 -LEADER
fixed length control field 04420cam a2200289 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250117193350.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Schillinger, Françoise
Relator term author
245 00 - TITLE STATEMENT
Title Impact des hyperleucocytoses sur les paramètres érythrocytaires de la numération : prise en charge par l’analyseur XN-10 RET
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2021.<br/>
500 ## - GENERAL NOTE
General note 24
520 ## - SUMMARY, ETC.
Summary, etc. RésuméIntroduction. Les hyperleucocytoses majeures peuvent interférer avec le dosage de l’hémoglobine, la numération des globules rouges et le calcul des constantes érythrocytaires. Les recommandations actuelles imposent diverses manipulations de l’échantillon, ce qui entraîne une grande variabilité inter-opérateur. Le but de notre étude était de définir une méthode automatisée sur l’automate XN-10 RET garantissant la rapidité et l’exactitude du résultat de l’hémogramme en cas d’hyperleucocytose majeure. Méthode.Les échantillons de 228 patients témoins sans hyperleucocytose, et de 81 patients présentant une hémopathie maligne avec une hyperleucocytose majeure ont été analysés sur l’automate XN-10 RET. Les résultats de l’hémoglobine en photométrie (Hb) des globules rouges en impédance (GR-I) et du VGM ont été comparés aux méthodes optiques (Hb-O et GR-O), ainsi qu’au R-MFV. Résultats. Le groupe témoin nous a permis de confirmer que les méthodes usuelles (photométrie et impédance) étaient corrélées aux méthodes optiques et au R-MFV. Parmi les patients présentant une hyperleucocytose majeure, les globules blancs (GB) des groupes leucémie lymphoïde chronique (LLC) et leucémie aiguë lymphoblastique (LAL) induisaient une interférence sur les GR-I et le VGM, pas sur l’Hb. Dans les groupes leucémie myéloïde chronique (LMC) et leucémies aiguës myéloïdes (LAM), les GB interféraient sur l’Hb, pas sur les GR-I ni sur le VGM. Les méthodes optiques et le R-MFV ont permis de corriger les différents paramètres concernés par l’interférence liée à l’hyperleucocytose. Conclusion. Nous proposons un arbre décisionnel s’appuyant sur des critères simples de déclenchement des mesures optiques et du R-MFV permettant de corriger rapidement les résultats des paramètres impactés par l’hyperleucocytose.
520 ## - SUMMARY, ETC.
Summary, etc. Introduction. Extreme hyperleukocytosis can interfere with the haemoglobin measurement, red blood cell counts and the calculation of the erythrocyte indices. Current recommendations require various sample manipulations, resulting in high inter-operator variability. The aim of our study was to define an automated method on the XN-10 RET analyser to ensure the speed and accuracy of the haemogram results reported in cases of extreme hyperleukocytosis. Method. Samples from 228 control patients without hyperleukocytosis and 81 patients with haematological malignancies with extreme hyperleukocytosis were analysed on the XN-10 RET analyser. The results of photometry haemoglobin (Hb), impedance red blood cells (RBC-I) and MCV were compared to the optical methods (Hb-O and RBC-O), as well as R-MFV. Results. The control group allowed us to confirm that the usual methods (photometry and impedance) were correlated with the optical methods and R-MFV. Among patients with extreme hyperleukocytosis, the white blood cells (WBC) in chronic lymphocytic leukaemia (CLL) and acute lymphoblastic leukemia (ALL) groups interfered with RBC-I and MCV but not with Hb. In chronic myeloid leukaemia (CML) and acute myeloid leukemia (AML) groups, WBC interfered with Hb and not with RBC-I nor MCV. The optical methods and R-MFV have corrected the various parameters affected by interference from hyperleukocytosis. Conclusion. We propose a decision tree based on simple criteria for triggering optical measurements and R-MFV to quickly correct the results of parameters impacted by hyperleukocytosis.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element arbre décisionnel
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element hémogramme
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element hyperleucocytose
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element interférence
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element XN-10 RET
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element cell blood count
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element interference
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element decision tree
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element hyperleukocytosis
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element XN-10 RET
786 0# - DATA SOURCE ENTRY
Note Annales de Biologie Clinique | 79 | 2 | 2021-03-01 | p. 181-189 | 0003-3898
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-annales-de-biologie-clinique-2021-2-page-181?lang=fr&redirect-ssocas=7080">https://shs.cairn.info/revue-annales-de-biologie-clinique-2021-2-page-181?lang=fr&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025