Comparison of blood gas results obtained on Abbott i-Stat® and on Radiometer ABL 800 Flex® analyzers Impact for the clinical decision (notice n° 276569)

détails MARC
000 -LEADER
fixed length control field 04083cam a2200289 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250117193902.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Jouffroy, Romain
Relator term author
245 00 - TITLE STATEMENT
Title Comparison of blood gas results obtained on Abbott i-Stat® and on Radiometer ABL 800 Flex® analyzers Impact for the clinical decision
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2022.<br/>
500 ## - GENERAL NOTE
General note 48
520 ## - SUMMARY, ETC.
Summary, etc. ContexteLes dispositifs médicaux de biologie délocalisée peuvent être utiles pour évaluer la gravité et aider au triage des patients à la fois en milieu hospitalier mais aussi en milieu préhospitalier. Avant leur utilisation, les performances analytiques de ces dispositifs médicaux doivent être comparées aux méthodes de référence des laboratoires hospitaliers. Dans cette étude, nous décrivons la comparabilité des résultats obtenus soit par le dispositif portable Abbott i-STAT® avec ceux fournis par l’analyseur de gaz du sang du laboratoire central de notre hôpital. MéthodesDes échantillons de sang provenant de 37 patients septiques admis en réanimation ont été analysés par le système Abbott i-STAT® et l’analyseur de laboratoire Radiometer ABL800 Flex®. Les paramètres étudiés étaient les suivants : pH, pO2, pCO2, excès de base (BE), HCO3 – et lactate. La comparabilité a été évaluée par la méthode de Bland-Altman. La valeur clinique de l’éventuelle inadéquation issue des différences de valeurs a également été évaluée. RésultatsDes corrélations tout à fait acceptables entre les résultats du système Abbott i-STAT® et de l’analyseur de laboratoire ont été observées, avec un R2 le plus souvent supérieur à 0,85. L’analyse Bland-Altman a montré un biais de 1,26 % pour le système Abbott i-STAT® par rapport aux résultats fournis par l’analyseur du laboratoire. ConclusionLe dispositif de biologie délocalisée Abbott i-STAT® est comparable et concordant avec l’analyseur de laboratoire Radiometer ABL800 Flex®. Le dispositif Abbott i-STAT® System POCT pourrait être utilisé en milieu préhospitalier afin d’évaluer la gravité de patients atteints de sepsis.
520 ## - SUMMARY, ETC.
Summary, etc. BackgroundPoint of care testing (POCT) tests are needed to assess severity and to help for triage in hospital and in prehospital settings. Before their use, the analytical performances of POCTs have to be compared with central laboratory reference methods. In this study, we describe the comparability of results obtained by either the Abbott i- STAT® System POCT handheld device or the blood gases analyzer of the central laboratory of our hospital. MethodsSample blood from 37 septic patients admitted to the intensive care unit (ICU) were assayed by Abbott i- STAT® System POCT and Radiometer ABL800 Flex® lab analyzer. Studied parameters were as follows: pH, pO2, pCO2, base excess (BE), HCO3 – and lactate. Comparability was evaluated using Bland-Altman method. The clinical value for possible mismatch issued of values differences was also assessed. ResultsQuite acceptable correlations in results of POCT and laboratory analyzer were observed with R2 most of time above 0.85. Bland-Altman analysis showed a bias of 1.26% for Abbott i- STAT® System POCT vs laboratory. ConclusionAbbott i- STAT® System POCT handheld device is comparable to Radiometer ABL800 Flex® lab analyzer and concordant with laboratory analysis. Abbott i- STAT® System POCT handled device could be used in the prehospital settings in order to evaluate the severity of sepsis.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element sepsis
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element comparabilité
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element biologie délocalisée
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element POCT
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element comparability
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element sepsis
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Laney, Maude
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Leguillier, Teddy
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Nivet-Antoine, Valérie
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Beaudeux, Jean-Louis
Relator term author
786 0# - DATA SOURCE ENTRY
Note Annales de Biologie Clinique | 80 | 6 | 2022-12-01 | p. 521-525 | 0003-3898
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-annales-de-biologie-clinique-2022-6-page-521?lang=en&redirect-ssocas=7080">https://shs.cairn.info/revue-annales-de-biologie-clinique-2022-6-page-521?lang=en&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025