Image de Google Jackets
Vue normale Vue MARC vue ISBD

De novo status epilepticus possibly related to battery depletion of anterior thalamic brain stimulator

Par : Contributeur(s) : Type de matériel : TexteTexteLangue : français Détails de publication : 2022. Sujet(s) : Ressources en ligne : Abrégé : Anterior thalamic deep brain stimulation is an effective therapeutic option for patients with drug-refractory focal epilepsy who are poor surgical candidates. Although the precise mechanism of action of thalamic neurostimulation is unknown, studies demonstrating increased efficacy over time have raised the possibility that therapeutic benefits are mediated by stimulation-related long-term neuroplastic changes. Adverse effects related to hardware malfunction have been previously described, and most commonly include local infection, sensory disturbances, and migration of leads. However, the withdrawal effect of sudden deep brain stimulation malfunction on seizure control is unclear. We present the case of a 21-year-old patient with intractable focal epilepsy who developed status epilepticus concurrently with unexpected deep brain stimulator battery failure, 21 months post implantation. This case demonstrates an unfamiliar possible adverse effect of anterior thalamic stimulation withdrawal and emphasizes the importance of stimulator hardware assessment in patients presenting with seizure worsening.
Tags de cette bibliothèque : Pas de tags pour ce titre. Connectez-vous pour ajouter des tags.
Evaluations
    Classement moyen : 0.0 (0 votes)
Nous n'avons pas d'exemplaire de ce document

21

Anterior thalamic deep brain stimulation is an effective therapeutic option for patients with drug-refractory focal epilepsy who are poor surgical candidates. Although the precise mechanism of action of thalamic neurostimulation is unknown, studies demonstrating increased efficacy over time have raised the possibility that therapeutic benefits are mediated by stimulation-related long-term neuroplastic changes. Adverse effects related to hardware malfunction have been previously described, and most commonly include local infection, sensory disturbances, and migration of leads. However, the withdrawal effect of sudden deep brain stimulation malfunction on seizure control is unclear. We present the case of a 21-year-old patient with intractable focal epilepsy who developed status epilepticus concurrently with unexpected deep brain stimulator battery failure, 21 months post implantation. This case demonstrates an unfamiliar possible adverse effect of anterior thalamic stimulation withdrawal and emphasizes the importance of stimulator hardware assessment in patients presenting with seizure worsening.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025