Évaluation en vie réelle de la mesure de troponine I hypersensible sur un système de biologie délocalisée pour un service d’urgences (notice n° 276461)

détails MARC
000 -LEADER
fixed length control field 04821cam a2200349 4500500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250117193829.0
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title fre
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Mottin, Léo
Relator term author
245 00 - TITLE STATEMENT
Title Évaluation en vie réelle de la mesure de troponine I hypersensible sur un système de biologie délocalisée pour un service d’urgences
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2023.<br/>
500 ## - GENERAL NOTE
General note 77
520 ## - SUMMARY, ETC.
Summary, etc. Résumé Les recommandations récentes de l’ESC introduisent la possibilité de réaliser des cycles rapides de troponine dans le cadre d’une suspicion d’un SCA ST-. Ces recommandations offrent la possibilité d’utilisation de systèmes délocalisés sous réserve qu’ils aient une grande sensibilité analytique. L’objectif de notre étude est d’évaluer en vie réelle la faisabilité et les performances d’un dosage de troponine I-hs (TnI-hs, Atellica® VTLi, Siemens) délocalisé comparé aux valeurs obtenues de troponine T-hs (TnT-hs, e602®, Roche) pour des patients consultant dans un service d’urgences. Les CV de répétabilité et reproductibilité de la TnI-hs sont inférieurs à 10 %. La comparaison des deux troponines est modérée (r = 0,7). Les 117 patients inclus dans l’étude ont un âge médian de 65 ans, 30 % sont insuffisants rénaux et 36 % consultent pour douleur thoracique. Dans notre étude, la TnT-hs est plus souvent supérieure au 99e percentile que la TnI-hs et ceux même pour un 99e percentile de TnT-hs adapté à l’âge. La concordance des résultats est modérée (Kappa de Cohen : 0,54), l’âge restant la valeur explicative la plus importante des discordances. Seule la TnT-hs présente une valeur prédictive concernant l’hospitalisation. Nous n’avons pas observé de discordances d’interprétation pour les patients ayant eu une cinétique de troponine. Cette étude conforte la faisabilité d’utiliser un système de biologie délocalisée aux urgences sous réserve qu’il réalise une troponine hypersensible. Cependant, des données sont manquantes pour pouvoir l’utiliser dans le cadre d’algorithme rapide. Enfin, cette implémentation nécessite une collaboration clinico-biologique étroite tant sur l’organisation que sur l’interprétation des valeurs afin d’améliorer le service médical rendu au patient.
520 ## - SUMMARY, ETC.
Summary, etc. European Society of Cardiology (ESC) guidelines allow to perform rapid rule-in and rule-out algorithm with rapid troponin kinetics for the management of suspected Non ST-elevation acute coronary syndrome. These recommendations allow the use of point-of-care testing (POCT) systems provided that they have sufficient analytical performance. The aim of our study was to evaluate in real life the feasibility and performance of using a high sensitivity cardiac troponin I POCT system assay (hs-cTnI, Atellica® VTLi, Siemens) compared to high sensitivity cardiac troponin T values (hs-cTnT, e602®, Roche) obtained for patients admitted to emergency department. Analytical verification showed a coefficient of variation below 10% for hs-cTnI. Comparison of both troponins was moderate (r = 0.7). The study included 117 patients with a median age of 65 years, 30% had renal failure and 36% presented with chest pain. In this study, the hs-cTnT value was, more often, higher than the 99th percentile than the hs-cTnl value, even for an age-adjusted 99th percentile hs-cTnT value. The concordance of the results was moderate (Cohen’s Kappa: 0.54), age remaining the most important explanatory value of discordance. Only hs-cTnT had a predictive value for hospitalization. We did not observe any interpretation discrepancies for patients who had troponin kinetics. This study confirms the feasibility of using a POCT analyzer in the emergency department, provided that it performs high sensitivity troponin. However, some data are missing to be able to use it in the framework of rapid algorithm. Finally, the implementation of POCT requires collaboration between biologists and emergency physicians in terms of organization and interpretation of values, for the overall benefit of the patient.
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element troponine I
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element urgences
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element troponine T
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element biologie délocalisée
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element douleur thoracique
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element point of care
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element I troponin
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element emergency
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element T troponin
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element thoracic pain
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Kassimy, Iliasse Idrissi
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Girot, Hélène
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Leguillon, Romain
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Joly, Luc Marie
Relator term author
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Brunel, Valery
Relator term author
786 0# - DATA SOURCE ENTRY
Note Annales de Biologie Clinique | 81 | 2 | 2023-03-01 | p. 145-155 | 0003-3898
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://shs.cairn.info/revue-annales-de-biologie-clinique-2023-2-page-145?lang=fr&redirect-ssocas=7080">https://shs.cairn.info/revue-annales-de-biologie-clinique-2023-2-page-145?lang=fr&redirect-ssocas=7080</a>

Pas d'exemplaire disponible.

PLUDOC

PLUDOC est la plateforme unique et centralisée de gestion des bibliothèques physiques et numériques de Guinée administré par le CEDUST. Elle est la plus grande base de données de ressources documentaires pour les Étudiants, Enseignants chercheurs et Chercheurs de Guinée.

Adresse

627 919 101/664 919 101

25 boulevard du commerce
Kaloum, Conakry, Guinée

Réseaux sociaux

Powered by Netsen Group @ 2025